This post follows up on some initial testing done on 5:1 mechanical advantage systems used to tension tyrolean crossings done a few months ago. I suggest anyone who has not read that report catch up with it here before reading on as I don’t explain everything again here.
For this batch of testing I used the same site but rigged things using metal strops instead of rope loops. This would act more like the solid bolt anchors used underground and would nearly eliminate false readings from knots tightening.
I used 2 types of readily available Type A rope
- 11mm Mammut Performance semi-static
- 10mm Beal Antipodes / Industrie
The tests were repeated with 3 different progress capture devices
- Brand new Petzl Stop (rigged both fully and half threaded)
- 10 year old worn Petzl Stop fully rigged
- Brand new Petzl RIG
I created a 5:1 system on 10m section of rope using a Petzl Ascension jammer, Petzl Tandem pulley and a Petzl Partner pulley. These are all items that would likely be used by leaders underground or of similar type. No big rescue pulleys or prussics.
I pulled all of the tests on my own with un-gloved hands. I weight approx. 90kg and pulled as hard as I could using just hand grip.
The final tension in the line was estimated by hanging off it and the force on the jammer ascertained using a Rock Exotica Enforcer load cell measuring in kN.
11mm rope
New Petzl Stop – fully rigged
2.06kN
2.10kN
New Petzl Stop – half rigged
1.96kN
2.04kN
Old Petzl Stop – fully rigged
2.04kN
2.04kN
Petzl RIG – belay mode
1.94kN
2.08kN
10mm Rope
New Petzl Stop – fully rigged
1.88kN
1.88kN
New Petzl Stop – half rigged
1.70kN
1.82kN
Old Petzl Stop – fully rigged
1.98kN
1.92kN
Petzl RIG – belay mode
1.78kN
1.80kN
There clearly was a drop off in force required to tension a 10mm system over the 11mm system, although only small. The fully rigged Petzl Stops required the highest force to tension although the old Stop in the 10mm test oddly required more than the new one (*see foot note).
I took the highest force generating configuration and added some more people to the pulling end.
11mm rope with a fully threaded brand new Petzl Stop
2 smaller adults pulling
2.00kN
2.22kN
2.34kN
2 small adults & myself pulling
3.56kN
3.24kN
3.54kN
I think it is entirely possible to exceed the 4kN figure if 3 large and/or strong adults were to be pulling on a 5:1 tensioning system. Both ropes used were clean and supple, with a dusty rope friction would again increase and coupled with some less efficient pulleys might tip the force higher still. I think that it is still appropriate to give out the advice that no more than 2 people are used to tension 5:1 systems, perhaps 3 if using youths or very small adults but certainly no more. The force required to damage a rope at the teeth of the jammer is rather large, especially on 11mm rope, but repeated tensioning on the same spot in the rope may, over time, lead to degredation of the rope.
The best advice I can give is to echo what is already taught at LCMLA and CIC:
- Keep your pulling ratios at 5:1 or lower and don’t exceed 10 men equivalent pulling power. i.e. 3:1 with 3 pulling or 5:1 with 2 pulling.
- Keep ropes clean and supple.
- Use only Type A ropes compatible with your choice of progress capture device.
- Thick ropes are stronger and stretch less but require more force to initially tension.
- Thinner ropes are strong enough but stretch a little more and require less force to initially tension.
- Where very high tension systems are required consider doubling up on ropes and using a non-toothed rope clamp like a prussic or Petzl Shunt / Rescuecender.